Search results for "Breath tests"

showing 10 items of 68 documents

Factors that influence exhaled nitric oxide in Italian schoolchildren

2008

Conflicting results exist about the meaning of exhaled nitric oxide (eNO) in epidemiologic studies, mainly because of the numerous factors that may affect the measurement.To evaluate the role of the factors that influence eNO levels in a sample of schoolchildren with or without respiratory diseases. We studied 335 schoolchildren, ages 10 to 16 years, from 8 schools in Palermo, Italy. After a respiratory questionnaire was completed, spirometry, skin tests, and eNO measurements were performed.Among 335 children, 13.7% reported symptoms of bronchial asthma, 46.9% reported symptoms of rhinitis, and 39.4% were asymptomatic. The ratio of forced expiratory volume in 1 second to forced vital capaci…

Pulmonary and Respiratory MedicineSpirometryHypersensitivity ImmediateMalemedicine.medical_specialtyPediatricsVital capacityBreath TestAdolescentImmunologySex FactorNitric OxideAsymptomaticAtopySex FactorsInternal medicineSex Factors; Skin Tests; Exhalation; Humans; Asthma; Rhinitis; Child; Italy; Nitric Oxide; Cross-Sectional Studies; Spirometry; Allergens; Hypersensitivity Immediate; Adolescent; Breath Tests; Female; MalemedicineImmunology and AllergyHumansRespiratory systemChildSensitizationRhinitiAsthmaRhinitisSkin TestsCross-Sectional Studiemedicine.diagnostic_testSkin Testbusiness.industryAllergenAllergensmedicine.diseaseAsthmamedicine.anatomical_structureCross-Sectional StudiesBreath TestsItalyExhalationSpirometryExhaled nitric oxideFemalemedicine.symptombusinessHuman
researchProduct

Modular Breath Analyzer (MBA): Introduction of a Breath Analyzer Platform Based on an Innovative and Unique, Modular eNose Concept for Breath Diagnos…

2021

Exhaled breath analysis for early disease detection may provide a convenient method for painless and non-invasive diagnosis. In this work, a novel, compact and easy-to-use breath analyzer platform with a modular sensing chamber and direct breath sampling unit is presented. The developed analyzer system comprises a compact, low volume, temperature-controlled sensing chamber in three modules that can host any type of resistive gas sensor arrays. Furthermore, in this study three modular breath analyzers are explicitly tested for reproducibility in a real-life breath analysis experiment with several calibration transfer (CT) techniques using transfer samples from the experiment. The experiment …

calibration transferComputer scienceRespiratory SystemPharmaceutical ScienceOrganic chemistrycorrelation alignment01 natural scienceseNoseAnalytical Chemistry0302 clinical medicineQD241-441DDC 570 / Life sciencesDrug Discoverybreath analysisSensortechnikdigestive oral and skin physiologyAtemgasanalyseMischoxideExhalationChemistry (miscellaneous)piecewise direct standardization030220 oncology & carcinogenesisElektronische NaseCalibrationMolecular MedicineMOX sensorsSpectrum analyzerAdolescentlow sensing chamber volumeReal-time computingstandard samplesbreath samplingArticleElectronic nose03 medical and health sciencesddc:570Breath testsCalibrationHumansddc:610Physical and Theoretical ChemistryReproducibilitybusiness.industry010401 analytical chemistryBreath samplingpattern recognitionBreath diagnosticsAtemluftModular design0104 chemical sciencesBreath analyzerBreath gas analysisbusinessBiosensing techniquesDDC 610 / Medicine & healthBiomarkersMolecules
researchProduct

Effect of Salmeterol on Seasonal Changes in Airway Responsiveness and Exhaled Nitric Oxide in Pollen-Sensitive Asthmatic Subjects

2002

Objective Using a model of natural allergen exposure, we examined the effect of regular treatment with salmeterol on allergen-induced changes in airway responsiveness and exhaled nitric oxide (ENO). Design Double-blind, randomized, parallel-group study. Setting Specialist allergy unit in a university hospital. Patients Asthmatic patients sensitized to pollen allergens were randomly allocated to monotherapy with salmeterol (n = 14) or placebo (n = 13). Interventions Salmeterol, 25 μg, and placebo inhalers, two puffs bid, for 6 weeks. Measurements Spirometry, the level of a provocative concentration of a substance (methacholine) causing a 20% fall in FEV 1 (PC 20 ), the PC 20 level for adenos…

AdultMalePulmonary and Respiratory MedicineSpirometrymedicine.medical_specialtyAdolescentmedicine.drug_classNitric OxideCritical Care and Intensive Care MedicinePlaceboDouble-Blind MethodForced Expiratory VolumeInternal medicineBronchodilatorAdministration InhalationmedicineHumansAlbuterolExpirationSalmeterol XinafoateAsthmamedicine.diagnostic_testbusiness.industryAirway ResistanceRhinitis Allergic SeasonalMiddle Agedrespiratory systemmedicine.diseaseAdenosine MonophosphateAsthmarespiratory tract diseasesEndocrinologyBreath TestsExhaled nitric oxideFemaleMethacholineSeasonsSalmeterolCardiology and Cardiovascular Medicinebusinessmedicine.drugChest
researchProduct

Whole Cow’s Milk but Not Lactose Can Induce Symptoms in Patients with Self-Reported Milk Intolerance: Evidence of Cow’s Milk Sensitivity in Adults

2021

Background: Lactose intolerance is the most frequent food intolerance, but many subjects with self-reported milk intolerance (SRMI) are asymptomatic at lactose hydrogen breath test (LHBT). The aim of this study was to evaluate the frequency of lactose intolerance in SRMI patients and their clinical characteristics. Methods: In a retrospective study, the clinical records of 314 SRMI patients (259 females, mean age: 39.1 ± 13.5 years) were reviewed; 102 patients with irritable bowel syndrome (IBS) served as controls. In a prospective study, 42 SRMI patients, negatives at the LHBT, underwent a double-blind, placebo-controlled (DBPC) whole cow’s milk challenge. Results: In the retrospective stu…

AdultMalemedicine.medical_specialtyPlaceboGastroenterologyAsymptomaticArticleduodenal histologyIrritable Bowel Syndromechemistry.chemical_compoundDouble-Blind Methodself-reported milk intoleranceIBSInternal medicinemedicineAnimalsHumansTX341-641Prospective StudiesLactoseProspective cohort studyCow’s milk protein allergy Duodenal histology HLA IBS Lactose hydrogen breath test Lactose intolerance Self‐reported milk intoleranceIrritable bowel syndromeRetrospective Studieslactose hydrogen breath testLactose intoleranceNutrition and Dieteticsmedicine.diagnostic_testNutrition. Foods and food supplybusiness.industrymedicine.diseaseHLAFood intolerancelactose intoleranceMilkBreath TestschemistryFemaleSelf ReportMilk Hypersensitivitymedicine.symptombusinessHydrogen breath testcow’s milk protein allergyFood ScienceNutrients
researchProduct

Comparison of isotope ratio mass spectrometry and nondispersive isotope-selective infrared spectroscopy for 13C-urea breath test.

1999

The 13C-urea breath test (UBT) is a sensitive and noninvasive method to diagnose Helicobacter pylori infection, but mass spectrometry (IRMS) is very expensive. The aims of this study were to compare the new low-priced infrared spectroscopy with IRMS in detecting the infection and to assess the influence of feeding on test accuracy.One hundred thirty-four patients with dyspeptic symptoms were recruited. Of these, 74 were infected and 60 uninfected on the basis of both CLO-test and histology. A subgroup of 37 patients (22 H. pylori-positive and 15 H. pylori-negative) was studied under fasting and nonfasting conditions on two different days. Duplicate breath samples were analyzed with two IRMS…

MalePathologymedicine.medical_specialtySpectrophotometry InfraredAnalytical chemistryInfrared spectroscopyMass spectrometrySensitivity and SpecificityMass Spectrometry13C urea breath testHelicobacter Infectionschemistry.chemical_compoundmedicineHumansUreaIsotope-ratio mass spectrometryDyspepsiaBreath testCarbon IsotopesHepatologymedicine.diagnostic_testIsotopeHelicobacter pyloribusiness.industryGastroenterologyMiddle AgedchemistryBreath TestsDuodenal UlcerUreaFemalebusiness
researchProduct

Negative Effect of Ranitidine on The Results of Urea Breath Test for The Diagnosis of Helicobacter Pylori

2001

In analogy with proton pump inhibitors, H2-antagonists may also be responsible for false-negative results on urea breath test for the detection of Helicobacter pylori. In this study we assessed the frequency and duration of false-negative urea breath tests in patients given different doses of ranitidine.A total of 120 consecutive dyspeptic patients infected with H. pylori on the basis of concomitant positive results of CLO-test, histology and urea breath test were recruited for this prospective, open, parallel-group study performed in an urban university gastroenterological clinic. They were randomized to receive an acute treatment with either ranitidine 300 mg once a day in the evening, ra…

Malemedicine.medical_specialtyTime FactorsUrea breath testSpirillaceaeRanitidineGastroenterologyHelicobacter InfectionsRanitidinechemistry.chemical_compoundInternal medicinemedicineHumansUreaProspective StudiesDyspepsiaFalse Negative ReactionsBreath testCarbon IsotopesDose-Response Relationship DrugHelicobacter pyloriHepatologymedicine.diagnostic_testbiologybusiness.industrydigestive oral and skin physiologyFalse Negative ReactionsGastroenterologyMiddle AgedHelicobacter pyloribacterial infections and mycosesHelicobacter Infectionsbiology.organism_classificationBreath TestsHistamine H2 AntagonistschemistryUreaFemalebusinessmedicine.drugAmerican Journal of Gastroenterology
researchProduct

Volatile organic compounds (VOCs) in exhaled breath as a marker of hypoxia in multiple chemical sensitivity

2021

Abstract In the history of diagnostics, breath analysis was one of the first method used until the breakthrough of biochemical testing technology. Today, breath analysis has made a comeback with the development of gas analyzers and e‐noses, demonstrating its power in its applicability for diagnosing a wide range of diseases. The physical basis of multiple chemical sensitivity (MCS), an emerging environmental disease, is difficult to understand because it is based on the scenario of chronic hypoxia, with a complex of chemical compounds that trigger the syndrome and result in multiple symptoms. The aim of this study was to investigate MCS by analyzing exhaled volatile organic compounds (VOCs)…

AdultMalePhysiologyhyperventilationmultiple chemical sensitivityORT test-VOCsBreath testingPhysiology (medical)medicineBiochemical testingHumansQP1-981Breath testVolatile Organic CompoundslactateChromatographymedicine.diagnostic_testChemistryhypoxiaVOCsHypoxia (medical)Middle Agedmedicine.diseaseChronic hypoxiaIncreased lactateORT test‐VOCsBreath gas analysisBreath TestsExhalationFemalemedicine.symptomMultiple chemical sensitivityBiomarkersPhysiological Reports
researchProduct

Passive exposure to nicotine from e-cigarettes

2016

A procedure based on the use of ion mobility spectrometry (IMS), after liquid-liquid microextraction (LLME), has been successfully employed for the determination of passive exposure to nicotine from cigarette and e-cigarette smoking. Nicotine has been determined in exhaled breath and oral fluids of both, active and passive smokers. The aforementioned studies, made in closed environments, evidenced that the exhaled breath after conventional blend cigarette smoke provides nicotine levels of the order of 220 ng per puff, in the case of experienced smokers, being exhaled only 32 ng in the case of e-cigarettes. On the other hand, the nicotine amount in oral fluids of passive vapers was between 8…

Bodily SecretionsNicotineLiquid Phase MicroextractionElectronic Nicotine Delivery Systems01 natural sciencesAnalytical ChemistryNicotine03 medical and health sciences0302 clinical medicinemedicineHumansCigarette smoke030212 general & internal medicineChromatographyChemistry010401 analytical chemistryEnvironmental ExposurePassive ExposureEnvironmental exposureExhaled air0104 chemical sciencesBreath TestsOral fluidTobacco Smoke PollutionBodily secretionsmedicine.drugTalanta
researchProduct

Zespół przerostu bakteryjnego jelita cienkiego

2021

Zespół przerostu bakteryjnego jelita cienkiego (SIBO) jest heterogennym zespołem charakteryzującym się wzrostem liczby i/lub obecnością nietypowych bakterii w jelicie cienkim. Na złożoną etiologię SIBO składają się zaburzenia ochronnych mechanizmów przeciwbakteryjnych jak zmniejszona kwaśność soku żołądkowego, zewnątrzwydzielnicza niewydolność trzustki, zespoły niedoboru odporności oraz nieprawidłowości anatomiczne jak niedrożność jelita cienkiego, uchyłki, przetoki, hirurgiczna ślepa pętla, wcześniejsze resekcje krętniczo-kątnicze oraz zaburzenia ruchliwości. Objawy kliniczne SIBO mogą być niespecyficzne. Najczęściej występuje niestrawność, biegunka, wzdęcia, dyskomfort w jamie brzusznej. …

mikrobiotaSIBOIBSmicrobiotazespół przerostu bakteryjnego jelita cienkiegohydrogen breath testssmall intestine bacterial overgrowthwodorowe testy oddechowePostępy Mikrobiologii
researchProduct

Porous materials applied to biomarker sensing in exhaled breath for monitoring and detecting non-invasive pathologies

2020

International audience; Overview of the use of porous materials for gas sensing to analyze the exhaled breath of patients for disease identification.The quantification of specific gases among thousand of VOCs (Volatile Organic Compounds) present in the human breath at the ppm/ppb level can be used to evidence the presence of diseases in the human body. The detection of these biomarkers in human exhaled breath through a noninvasive approach is an important field of research which is still attracting important attention to this day. A portable device working at room temperature and usable directly on exhaled breath samples is still a challenge requiring a sensing material with high performanc…

Materials scienceCrystalline materialsNon invasiveNanotechnology[CHIM.MATE]Chemical Sciences/Material chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyHighly selective01 natural sciences0104 chemical sciencesInorganic Chemistry[CHIM.POLY]Chemical Sciences/PolymersBreath TestsExhalationLimit of DetectionHighly porousHumans[CHIM.COOR]Chemical Sciences/Coordination chemistry[SDV.IB]Life Sciences [q-bio]/Bioengineering0210 nano-technologyPorous mediumPorosityBiomarkersDalton Transactions
researchProduct